Say proseso na panagpaliis na Oasis Bingfeng's hybrid flow dual-inletsarado-circuit cooling towermangirerepresenta na sakey a komplikadon agawaan ed thermodynamic engineering. Diad panamegley na intelihentin pankokolaboraan ed taloran nanduruman yugtan, nagawaan toy epektibon tuloy tan makatipid na enerhiya. Say nikadkaduma to et diad pankakasakey ya pangiyaplika na prinsipyo na counterflow tan crossflow heat exchange, ya inlaok ed dual-inlet air structure, ya manggagawa ed proseso na panagpaliis ya mas sientipiko tan makatunongan.


Phase 1: Pre-cooling Phase (Dry Operation)

No say atagey a temperatura na sirkulasyon na danum (kaslakan et 55-65℃) et onloob ed saray akasara ya heat exchange coil manlapud sistema, onggapo so proseso na panagpaliis. Diad sayan punto, saray axial fans ya akapuesto ed duaran dapag na tori et onggapon mankimey, ya mangaala na dakel ya dagem diad panamegley na dual-inlet design. No ikompara ed ordinaryon single-inlet ya istruktura, sayan desinyo et mamaaligwas na dagem na masulok ya 40%, ya manggagawa na pareparehon layer na dagem ed paway na tapew na saray coil.

Say dagem tan say ambetel a danum ed loob na saray coil et mansasalat na petang panamegley na prinsipyo na counterflow: say ambetel a danum et onloob manlapud tagey na saray coil, say ambetel a danum et onloloob manlapud leksab, tan say dagem et onaagus manlapud leksab, a mamawala na perpekton countercurrent heat exchange. Diad sayan yugtan, say panmatalek labat ed panagpaliis na dagem et makapangibawas na temperatura na danum na 5-8 degree, kanian matukoy itan parad panaon na primabera tan otonyo. Say nasukat ya datos et mangipapanengneng ya diad silong na 25℃tan 60% ya relatibon humidity,panagpaliis na dagemsay bukor to et makapangibawas na temperatura na danum manlapud 65℃ya anggad 57 degree.

复合流闭式冷却塔

Phase 2:Evaporative Cooling Phase(Wet Operation)

No ontagey so temperatura na kaliberliber odino saray proseso et mankaukolan na abeban temperatura na danum ya ompaway, say sistema et automatikon mangi-activate ed spray system. Saray eksakton inkadesinyo na saray nozzle et manporma na pareparehon water film ed paway na tapew na saray coil, ya mangigapo ed sankaimportantian ya yugtan na pansasalat na petang: say evaporative cooling.

Legan ya onlelereg so spray water manlapud tapew na coil, kada kilo na danum et mansesepsep na ngalngalin 2450 kJ na latent heat of vaporization. Sayan proseso na pananguman na phase et mangaawit na karaklan na petang manlapud loob na saray coil. Diad parehon panaon, say dual-inlet airflow et mamapeles na water film evaporation tan tampol ton ekalen so resulta na water vapor manlapud heat exchange area. Sayan hybrid flow design et mamapasimpli ed multi-dimensional heat exchange na danum tan dagem ed tapew na coil, ya mamaaligwas ed heat transfer efficiency na masulok ya 25% no ikompara ed single-flow designs.

闭式冷却塔降温过程

Phase 3: Deep Cooling Phase (Intelligent Adjustment)

No kaukolan ya palemewen so danum ya asingger ed temperatura na bombilya, say sistema et onloob ed deep cooling phase. Dia, say intelihentin sistema na panangontrol et automatikon mangi-adjust ed karakel na danum ya i-spray tan say kapeles na bentilador base ed saray parametro ya nabantayan a singa say pandumaan na temperatura na danum ya onloob tan say temperatura/init na kaliberliber.

Diad sayan yugtan, saray bentaha na hybrid flow et sigpot ya narealisar: say crossflow section et mangiseguro na atagey ya -flow heat exchange, bangta say counterflow section et makagamor na abeban temperatura na danum ya ompaway. Diad panamegley na eksakton panangontrol, say sistema et makapangipasen na temperatura na danum ya ompaway ed loob na ±0.5℃na niletneg a balor, ya sigpot a makasumpal ed saray kakaukolanen ed panangontrol na temperatura na saray eksakton proseso na industriya.

绿洲冰峰闭式冷却塔降温


Papel na Intelligent Control System

Say interon proseso na panagpalemew et eksakton nareregula na sakey ya intelihentin sistema na panangontrol. Say sistema et mankokolekta na 12 set na operational data kada segundo, kaiba lay:

Temperatura na ambeyan bombilya

Pandumaan na temperatura na danum ya onloob-

Say iyaagus na danum ya i-spray

Say kipapasen na operasyon na bentilador

Saray parametro na operasyon na bomba na danum

Base ed sayan datos, say control system et automatikon manpili na sankaabigan ya operating mode. Singa bilang, onsaliw itan ed puroair-cooling mode legan na ambetel iran oras na labiparad zero ya konsumo na danum tan intelihentin mangi-activate ed spray system legan na atagey a temperatura pian naseguro so inkaepektibo na panag-cool. Ipapanengneng na aktual ya datos na operasyon ya sayan intelihentin regulasyon et makapangibawas na tinaon ya komprehensibon konsumo na enerhiya na masulok ya 30% tan makatipid na danum na 40%.

闭式冷却塔智能


Resulta na Praktikal ya Aplikasyon

Diad praktikal ya aplikasyon ed sakey a planta na kemikal, sayan modelo nacooling towersay malet ya ambetel ya proseso na sirkulasyon na danum manlapud 60℃anggad 32℃diad silong na arawrawin kondisyon na 35℃ya temperatura na kaliberliber tan 80% ya relatibon humidity, ya sigpot ya makasumpal ed saray kakaukolanen ed proseso na produksyon. Say mas importante, diad panamegley na automatikon pangiyalis na intelihentin paraan na panag-operate, sayan kagawaan so akatipid ed negosyo na 15,000 tonelada na danum ed tinaon tan abawasan so gastos ed kuryente na masulok ya 200,000 RMB.

Sayan komplikadon proseso na panagpalamig so sigpot a mangipapanengneng ed 22 taon ya Oasis Bingfengteknikal ya kakabatandiadsarado-sirkito ya panagpaliislawak tan ipapanengneng toy direksion na iyaaligwas na modernon kagawaan ed industriya no nipaakar ed inkaepektibo tan inkadunong na enerhiya.